A practical application for monitoring methane in ambient air at waste disposal facillities using a portable open path analyzer

Authors

  • Noboru Tanikawa Hokkaido University, Japan
  • Toru Furuichi Hokkaido University, Japan
  • Kazuei Ishii Hokkaido University, Japan
  • Kohji Matsuo Hokkaido University, Japan

DOI:

https://doi.org/10.15626/Eco-Tech.2005.060

Keywords:

Methane; Open path type analyzer; Landfill site; Biogasification; Composting

Abstract

It is well known that methane (CH4) is a greenhouse gas, and one of the main gases emitted
from landfills, CH4 is also emitted from biogasification facilities and composting facilities, A
new method to monitor CH4 in ambient air has been developed using a portable open path
methane analyzer (POMA) that is retailed as an urban gas leak detector. In this study, we have
investigated a practical application of a POMA in the field, and the characteristics of CH4
emissions at landfill sites, biogasification facilities, and a composting facility,
It is clear that this new method is convenient, and can be used to monitor the average
concentration of CH4 in ambient air at a waste disposal facility, such as a landfill site, a
composting facility, or a biogasification facility, The concentration of CH4 in ambient air at
landfill sites, a composting facility, and biogasification facilities were found to be 2-30, 2-13,
and 3-13 ppm, respectively,